Sweden — AFS 2023:12 (workplaces)

Mandatory for workplaces. AFS 2023:12 (Utformning av arbetsplatser — "Design of workplaces") is issued by the Swedish Work Environment Authority (Arbetsmiljöverket) under the Work Environment Act (Arbetsmiljölagen) — a different legal basis and authority from BFS 2024:8, Boverket's building regulation under the Planning and Building Act (PBL).

The two apply in parallel to workplace buildings: BFS 2024:8 sets the building-permit requirement, and AFS 2023:12 sets the employer's duty of care toward people working in the space.

Requirement

AFS 2023:12 does not give a numeric daylight threshold. It requires that fixed workstations have sufficient daylight and a view of the outside, assessed according to the room's use, without specifying a daylight factor or an area percentage.

ItemValue
MetricNot specified in the binding rule; allmänna råd point to EN 17037
ThresholdNone stated in AFS 2023:12 itself — "sufficient daylight," assessed by use
Spaces coveredFixed workstations, defined desk areas
Spaces excludedAisles, break zones

AFS 2023:12's allmänna råd (general recommendations — non-binding guidance on how to meet the binding rule) point explicitly to the calculation method:

"Exempel på metoder för bedömning av dagsljus och utblick finns i standarden SS-EN 17037:2018, Dagsljus i byggnader. Utgåva 1. Den ger även rekommendationer om god dagsljusbelysning och utblick." ("Examples of methods for assessing daylight and view are given in the standard SS-EN 17037:2018, Daylight in buildings, Edition 1. It also gives recommendations on good daylight and view.")

So EN 17037 is the referenced assessment method — via allmänna råd, not a binding numeric rule of AFS 2023:12 itself. In practice, compliance checks apply one of two alternative criteria, assessed per room rather than pooled at the dwelling level: either EN 17037's own sDA 300/50 % method, or the residential criterion from BFS 2024:8DF ≥ 1.0 % over ≥ 50 % of the area — used as a proxy. Neither is written directly into AFS 2023:12; both are common conventions consistent with the allmänna råd's pointer to EN 17037.

Calculation setup

AFS 2023:12 sets no binding calculation method of its own; its allmänna råd point to EN 17037's daylight-provision method, and Swedish practice uses the same setup as BFS 2024:8.

ParameterValueNotes
Reference plane height0.8 m above floorBy convention, shared with BFS 2024:8
Grid spacing0.2–0.3 mCommon practice, not prescribed
Wall offset (excluded border)none
Sky modelCIE standard overcast sky

Reflectances are not mandated by AFS 2023:12; see Reflectance for the values LUX uses.

How LUX handles it

Status: ✅ Supported in LUX Live v0.3.0 (via the BFS 2024:8 proxy below).

LUX Live does not certify AFS 2023:12 compliance on its own legal terms — the regulation gives no number to check against. What LUX reports is the BFS 2024:8 DF ≥ 1.0 % criterion applied per room instead of pooled per dwelling, which is the practical proxy used for workplace assessments. This runs on the DF Default model — the only validated model, in production use.