Mandatory. BR18 (Bygningsreglementet 2018) is the Danish building regulation. Daylight and view out are covered by Chapter 18, §§ 378–381. The regulation gives two separate functional requirements — view out (§378) and daylight (§379) — plus an exemption (§380) and a solar-overheating/glare provision (§381). The guidance (vejledning) to Chapter 18 sets out the calculation assumptions.

Requirement

View out (§378)

Work rooms, common rooms, teaching rooms, dwelling rooms, etc. must have windows positioned so that people in the room can see out to the surroundings. Windows and solar shading must be designed and built so that a satisfactory view out is maintained for a satisfactory part of the time the room is in use. LUX does not currently assess this requirement — it reports daylight only.

Daylight (§379)

Work rooms, common rooms in institutions, teaching rooms, dining rooms (together "work rooms, etc."), dwelling rooms and kitchens must have enough daylight access that the rooms are sufficiently lit. Compliance is shown by one of these routes:

RouteMetricThreshold
A — glazing area (primary/simplified method)Glass area, corrected for shading and light transmittance per the vejledning≥ 10 % of the relevant floor area, with no shading assumed before correction
B — dynamic illuminance (EN 17037 method)Illuminance / DA300 lx reached over ≥ 50 % of the relevant floor area for ≥ 50 % of the daylight hours
C — other methodsAnyAccepted if it can otherwise be documented that the room is sufficiently lit — this is where a daylight factor calculation fits in practice, though §379 does not name a DF threshold itself
ItemValue
Assessment levelPer room
Relevant floor area — dwelling roomsThe internal floor area of the room
Relevant floor area — work rooms etc.Only the area where workstations are placed
Exemption (§380)The daylight requirement can be waived where meeting it would be a decisive disadvantage to the business's operation — e.g. where the nature of production does not allow daylight
Solar overheating/glare (§381)Windows must be designed, placed and, where needed, shaded so that sunlight through them does not cause overheating or direct-sun nuisance — not assessed by LUX today

The DF ≥ 2.1 % figure previously listed here as "Route A" does not appear in §379 itself — the law's own primary route is the 10 % glazing-area method. 2.1 % may come from a vejledning-derived DF equivalent to that glazing ratio, but this needs confirming against the current guidance text before being restated as a named threshold; flagged with ?? below.

ItemValue
Possible DF equivalent (unconfirmed)?? — a DF figure around 2.1 % has circulated as a rule-of-thumb equivalent to the 10 % glazing rule, but is not itself in §379 or confirmed against the current vejledning

Calculation setup

ParameterValueNotes
Reference plane height0.5 m above floorBR18 guidance (differs from EN 17037's 0.85 m) — ?? confirm against current vejledning
Grid spacing0.2–0.3 mCommon practice, not prescribed; BR18 guidance is expected to reference the EN 17037 grid, not yet confirmed
Wall offset (excluded border)0.5 m
Sky modelRoute B: climate-based (Perez, hourly weather file) · a DF-based check would use CIE standard overcast

Reflectances are not stated in BR18/vejledning; see Reflectance for the values LUX uses.

How LUX handles it

Status: 🔜 Planned, not yet supported in LUX Live v0.3.0.

A daylight-factor check (Route C, "other methods") maps directly onto the existing LUX daylight-factor output once the DF equivalent figure above is confirmed; Route A (glazing area) is a simple geometric check LUX does not currently perform; Route B needs the climate-based illuminance pipeline.